Wireless Tunnel™ Radio Sensor based on LoRa™ Technology
Wireless Temperature and Humidity Monitoring
Ensure that your environmental conditions are within required parameters, log and graph data over time, and receive realtime alerts when user defined sensor thresholds are exceeded. Use as a data logger with data buffered and synchronized to gateway when in range. IP66 rated enclosure provides weatherproofing for use in outdoor environments. Mounting with DIN rail, wall hang or cable-tie / pipe clamp. Pair with any AKCP Wireless Tunnel™ gateway.
Sensor Options
- 4x AA Battery powered, with 10 yetar life*
- 4x AA Batteries with 10 year guaranteed battery life*
- 5VDC or 12VDC powered
- IP66 rated waterproof enclosure
- LED indicators for power, status andd RSSI
- Optional DIN rail or pipe mounting accessories
- Optional cable up to 15ft for sensor placement
Wireless Tunnel™ Monitoring Solutions
*10 years at 25°C broadcasting every 15 minutes. Batteries not included.
LBTH-xx
Dual temp and humidity sensor with sensor on custom length cable from 1ft up to 15ft.
For custom length order LBTH-xx where xx is cable length.
LBTHD-xx-yy
Dual temp and humidity sensor with sensor on custom length cable from 1ft up to 15ft.
Dry contact input with door contact on custom cable from 1ft to 15ft.
For custom order, LBTHD-xx-yy where xx is THS length and yy is dry contact length.
Status Indication | LED indication for – Mode – Status – RSSI |
Components | Manufactured using highly integrated, low power surface mount technology to ensure long term reliability. |
Operating Environment | Temperature : Min. -35° C – Max.80° C Humidity: Min. 20% – Max. 80% (Non-Condensing) |
LoRa (R) Radio Regional plans |
– EU868 : 863~868Mhz, Max TX Power +14dBm, Duty Cycle 1% – US915: 903~915Mhz, Max TX Power +17dBm – AS923 : 920~925Mhz, Max TX Power +14dBm, Duty Cycle 1% – KR920 (Korea) : 922~923Mhz, Max TX Power +14dBm, Duty Cycle 1% – IL917 (Israel) : 915~917Mhz , Max TX Power +14dBm, Duty Cycle 1% |
Certification | FCC Part15C, CE EN300220-2 |
Interface | Micro-USB port for powering, adding and upgrading to the Gateway base unit |
Dimension |
76 x 77 x 120mm |
Mounting |
Wall hanging, DIN rail, Pipe Clamp |
Power source |
4xAA batteries or via micro-USB port |
Power Consumption | Average 12 mWatt, 10uA in Idle, up to 10 years battery life |
Temperature | |
Measurement Range |
-40°C to +75°C -40°F to +167°F |
Measurement Resolution |
0.1°C increments 0.2°F increments |
Measurement Accuracy | Typical : * ±0.3 from -40ºC to +75ºC * ±0.4 from -40ºF to +167ºF Maximum : * ±0.4 at -40ºC and ±0.4 at +75ºC * ±0.7 at -40ºF and ±0.7 at +167ºF |
Humidity |
|
Measurement range |
0 to 100% Relative humidity |
Resolution |
1%RH increments, 0.01%RH sensor reading |
Accuracy at | 25°C ±2%RH |
Gateway sensor count | 5 (3 + 2) |