Battery Monitoring Sensor
Battery Monitoring Sensor

Battery Health Sensor

Battery Monitoring Sensor for monitoring the voltage, temperature, and current load for batteries and DC power systems.

The Battery Monitoring Sensor monitors an individual cell or bank of batteries, as well as DC power systems like solar panel arrays. With Battery Monitoring Sensor, you can monitor:-

  • The temperature of the battery terminals
  • The voltage output from batteries or panel array
  • Current load on batteries or charging circuit

Typical applications would be for battery monitoring, solar panel array, or generator starter batteries.

Product Code : BATTMON

Battery Health Sensor
Generator-Battery

Place the Battery Monitoring Sensor on your generator starter battery. Monitor the crank current from the starter motor, battery voltage, and temperature, or monitor the alternator charge current, voltage, and battery temperature.

This can be used as a diagnostic tool to identify a battery that needs replacing or a problem with the alternator or starter motor.

For example, a decreasing crank current may be a sign that the battery although still having sufficient voltage does not have enough power output to crank the engine, resulting in a failure to start situation.

Monitoring of your complete solar panel system from end to end is possible by deploying multiple Battery Monitoring Sensors.

Solar Panel Array
Monitor the voltage and current output from your panels. Identify if they are running at less than optimum efficiency, for example, if they are dirty and need cleaning.

Battery Stack
The Battery Monitor system monitors the output of voltage and current from the battery stack, as well as battery temperatures.

Charge Status
By comparing the battery current load and the solar panel charging load you can identify if your system is providing sufficient charging power if you are draining your batteries, and if so at what rate they are being consumed.

Solar-Panel-System and

Specifications

Mounting DIN rail mounting
Screw mounting
Power Input Voltage and Current ratings :

Voltage: 0~60VDC (3 configurable ranges: 0~15V, 0~30V or 0~60V)
Current: external CT
+ 50A (standard)
+ 100A
+ 200A
+ 400A
+ 500A
+ 600A
+ 800A
+ 1000A
+ 1500A

Power Metering Voltage (V) : +/-0.05% Full-Scale, error +/-0.05% Full-Scale
Current (A) : +/-0.05% Full-Scale, error +/-0.05% Full-Scale
Temperature Drift: +/-0.02%/°C
Temperature Monitoring Temperature sensor with 1-meter cable
range -40°C to 75°C
Status Indication LED indication for power
LED indication for input presence
Operating Environment Temparature : Min. – 35°C – Max.80°C
Humidity : Min.20% – Max.80% (Non-Condensing)
Inputs 1x sensor RJ45 Port

Hardwired with following plugs :
– Phoenix connector for voltage
– Phoenix connector for temperature
– Phoenix connector for external current transformer

Battery Monitoring Sensor Technical Drawings

View Separately

Request a Quotation

Request a quotation from one of our experienced sales staff today.

AKCPBattery Monitoring Sensor