Yes, we offer two types of these sensors. The TMP01 and THS01 are the fixed one foot type and are only designed to be connected directly to the AKCP base … Read More
Can I connect these sensors through my RJ-45 CAT5/6 patch panels? Can I use those female to female CAT5 RJ-45 couplers to extend them?
No, we do not recommend you trying to connect any of our AKCP sensors including the temperature and dual temp humidity sensors though patch panels or using the RJ-45 couplers … Read More
Can AKCP provide me with the wiring diagrams for each sensor I have?
Wiring diagram and pinout for AKCP intelligent sensors? Yes, we have all the wiring diagrams for all of our Intelligent sensors. Please contact the AKCP Support Team at [email protected] for … Read More
Can AKCP provide me with CE certifications for your sensors?
Yes, we have CE certificates for most of our products. You can request them from the AKCP Sales Team at [email protected], or you can download them from our web site. … Read More
Can I connect third party sensors to my sensorProbe, or securityProbe?
Yes, actually, one of our greatest strengths is AKCP can provide a data collection center for many different third party sensors. Using our 4-20mA intelligent sensor, we can interface to … Read More
Can I connect a third party sensor using the 4-20mA sensor if it outputs more than 5 VDC?
Can I connect third party sensors with 4-20mA sensor? You can apply more than the 5VDC, but you need to be careful not to exceed the 20mA current. The 4-20mA … Read More
What is the accuracy of a 4-20mA converter?
The accuracy of our 4-20mA converters is 2%. The resolution of our 4-20mA converters is 0.1mA. You can use these figures in conjunction with your sensor?s accuracy to find the … Read More
I am sure that all settings for the Digital Voltmeter sensor are correct, but it seems to have error in the reading. How can I correct this error?
The Digital Voltmeter and 4-20mA sensors have an input as analog signal which will be converted to digital using an A/D converter. Normally, the A/D converter is calibrated in production … Read More
I just finished a calibration process, but the reading is still a little bit off. Is there any way to fine tune the reading?
In the calibration process, we set the offset of the reference voltage so that the raw analog read 500 when the input to the RJ45 port is 1.25 volts. However, … Read More
Do you have any sensor that is capable of reading the fluctuation of electricity, and send me reports?
How to monitor electricity fluctuations? We have a sensor that is capable of monitoring Voltage, Wattage and Amperage. This is our Power Meter Sensor. You can set alerts as with … Read More